{"id":866,"date":"2021-11-23T10:00:56","date_gmt":"2021-11-23T09:00:56","guid":{"rendered":"http:\/\/pbelaire.free.fr\/?page_id=866"},"modified":"2021-11-23T10:00:56","modified_gmt":"2021-11-23T09:00:56","slug":"les-pll-2","status":"publish","type":"page","link":"https:\/\/ordi-tech.fr\/index.php\/les-pll-2\/","title":{"rendered":"Les PLL"},"content":{"rendered":"\n<p class=\"has-text-align-left wp-block-paragraph\"><p style=\"text-align: justify;\">Les PLL (Phased Locked Loop) ou boucle \u00e0 verrouillage de phase sont les composants cl\u00e9s de la s\u00e9lection de bande, avec quelques modifications elles permettent d\u2019obtenir plus de canaux sur les postes C.B. afin d\u2019\u00e9couter d\u2019autres bandes car rappelons qu\u2019il est interdit de moduler en dehors des 40 canaux\u2026<\/p><\/p>\n\n\n<p class=\"has-text-align-left wp-block-paragraph\"><p style=\"text-align: justify;\">C\u2019est un circuit int\u00e9gr\u00e9 faisant office de synth\u00e9tiseur de fr\u00e9quence, avec une stabilisation de l\u2019oscillateur sur une fr\u00e9quence de r\u00e9f\u00e9rence g\u00e9n\u00e9r\u00e9e par un quartz.<br \/>Le synth\u00e9tiseur se programme en binaire (niveau logique haut=+5V et niveau logique bas =0V) \u00e0 l\u2019aide du bouton \u00ab\u00a0canaux\u00a0\u00bb et donne en sortie une tension stabilis\u00e9e alimentant la diode varicap du circuit d\u2019oscillation.<br \/>Cette tension varie en fonction du canal pr\u00e9s\u00e9lectionn\u00e9, par exemple sur le Pr\u00e9sident Wilson : Le canal 1 correspond \u00e0 la tension de varicap de 2V, le canal 40 \u00e0 celle de 4,6V. Il y a donc une variation de 2,6V entre le canal 1 et le canal 40 soit : 65mV d\u2019\u00e9cart entre 2 canaux voisins. Quelle pr\u00e9cision ! Quand on pense qu\u2019entre 2 canaux l\u2019\u00e9cart en fr\u00e9quence est de 10kHz et que le Wilson peut varier en fr\u00e9quence de +\/- 800Hz, cela fait une stabilit\u00e9 en tension inf\u00e9rieure ou \u00e9gale \u00e05,2mV en sortie du synth\u00e9tiseur. On comprend pourquoi il est important d\u2019avoir une alimentation bien r\u00e9gul\u00e9e de 13,8V +\/- 0,5V pour avoir la meilleure modulation possible.<\/p><\/p>\n\n\n<h4 class=\"wp-block-heading\"><strong>Comment reconna\u00eetre la PLL dans son poste CB ?<\/strong><\/h4>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">C\u2019est un circuit int\u00e9gr\u00e9 de 16 ou 18 broches, se situant \u00e0 proximit\u00e9 d\u2019une s\u00e9rie de diodes et de r\u00e9sistances ou d\u2019un r\u00e9seau de r\u00e9sistances. Les r\u00e9f\u00e9rences les plus couramment rencontr\u00e9es sont :<\/p><\/p>\n\n\n<ul class=\"wp-block-list\"><li>PLL02 ou PLL02a pour les TX Multimode, Pacific, Formac, Grant\u2026<\/li><li>MC 145106 pour les TX Jackson (mon pr\u00e9f\u00e9r\u00e9), SS-360, SS-3900\u2026<\/li><li>SM 5124 pour les TX Jimmy, Johnny, Harry et Wilson.<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">Les PLL les plus simples \u00e0 modifier en programmation sont les MC 145106, car elles sont command\u00e9es par des additionneurs MC 4008. Ces additionneurs permettent de d\u00e9caler en fr\u00e9quence de 10kHz par un simple niveau logique haut sur l\u2019entr\u00e9e \u00ab&nbsp;retenue&nbsp;\u00bb. Cette retenue incr\u00e9mente de 1 le nombre programm\u00e9 sur la PLL, on ajoute donc 10kHz \u00e0 la fr\u00e9quence d\u00e9j\u00e0 programm\u00e9e. Cette PLL poss\u00e8de 9 bits d\u2019entr\u00e9e, ce qui th\u00e9oriquement permet d\u2019avoir jusqu\u2019\u00e0 512 canaux\u2026 Eh oui, 2 \u00e9tats logiques puissance 9 = 512 possibilit\u00e9s, que nous exp\u00e9rimenterons plus tard, \u00e0 l\u2019aide d\u2019un Arduino\u2026<\/p><\/p>\n\n\n<h4 class=\"wp-block-heading\"><strong>Comment \u00e7a fonctionne ?<\/strong><\/h4>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">Prenons en exemple le Pr\u00e9sident Jackson, sur lequel nous avons 2 s\u00e9lecteurs : Le s\u00e9lecteur de canaux et le s\u00e9lecteur de bandes. Le premier permet de commuter sur 40 canaux, le second sur 5 bandes. Nous avons donc avec cet appareil 40\u00d75=200, mais o\u00f9 sont pass\u00e9s les 26 canaux manquants annonc\u00e9s sur le mat\u00e9riel d\u2019exportation ?<br \/>En effet les Jackson destin\u00e9s \u00e0 l\u2019exportation ont bien 226 canaux. Les bandes, en r\u00e9alit\u00e9, ne comportent pas 40 canaux mais 45. Les canaux suppl\u00e9mentaires sont appel\u00e9s canaux \u00ab&nbsp;bis&nbsp;\u00bb, on trouve donc les canaux : 3bis, 7bis, 11bis, 15bis et 19bis.<br \/>Ces canaux \u00ab&nbsp;bis&nbsp;\u00bb sont obtenus sur les appareils \u00e0 l\u2019aide du bouton \u00ab&nbsp;+10kHz&nbsp;\u00bb.<br \/>Et alors ? Ca fait 225 canaux s\u2019il y en a 45 par bande, non ? Oui, mais avec le commutateur +10kHz on obtient sur le dernier canal de la derni\u00e8re bande un canal de plus ! Donc : 226 canaux en tout et pour tout.<\/p><\/p>\n\n\n<h4 class=\"wp-block-heading\">Comment programme-t-on une PLL ?<\/h4>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">La programmation d\u2019une PLL s\u2019effectue simplement en additionnant un nombre binaire correspondant \u00e0 la fr\u00e9quence de base de la bande s\u00e9lectionn\u00e9e, \u00e0 un autre nombre binaire correspondant au canal s\u00e9lectionn\u00e9.<\/p><\/p>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Exemple 1<\/strong><\/td><td><strong>Canal 1<\/strong><\/td><td><strong>Bande C<\/strong><\/td><td><strong>R\u00e9sultat<\/strong><\/td><\/tr><tr><td>Code binaire<\/td><td>000000001<\/td><td>010011101<\/td><td>010011110<\/td><\/tr><tr><td>Code d\u00e9cimal<\/td><td>1<\/td><td>157<\/td><td>158<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Exemple 2<\/strong><\/td><td><strong>Canal 1<\/strong><\/td><td><strong>Bande D<\/strong><\/td><td><strong>R\u00e9sultat<\/strong><\/td><\/tr><tr><td>Code binaire<\/td><td>000000001<\/td><td>011001010<\/td><td>011001011<\/td><\/tr><tr><td>Code d\u00e9cimal<\/td><td>1<\/td><td>202<\/td><td>203<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<h4 class=\"wp-block-heading\">Nombre de canaux entre 2 bandes ?<\/h4>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">Code de la bande D moins code de la bande C = 202 \u2013 157 = 45 =&gt; il existe bien 45 canaux sur chaque bande : de 1 \u00e0 40 + 3bis + 7bis + 11bis + 15bis + 19bis.<\/p><\/p>\n\n\n<h4 class=\"wp-block-heading\">Est-il donc possible de rajouter des canaux \u00e0 son poste de CB 40 canaux ?<\/h4>\n\n\n<p style=\"text-align: justify;\">Oui, c\u2019est possible en ajoutant des diodes sur la matrice afin de programmer un ou des codes de bandes suppl\u00e9mentaires. Pour cela, il faut changer le commutateur ou en ajouter un. Exemple : sur un Pr\u00e9sident Jackson, si l\u2019on veut ajouter la bande F (SUP3) il faudrait programmer le code binaire : 100100100 sur la matrice\u2026 Mais cela est impossible car les additionneurs 4 bits ne sont que 2 et m\u00eame s\u2019il y a une retenue qui peut commander le bit de poids fort sur la PLL, le 9\u00e8me, le Jackson a atteint ses limites ! Du moins pour l\u2019instant\u2026 Cependant selon le poste CB, nous serons limit\u00e9s par le VFO et d&rsquo;autres \u00e9l\u00e9ments qu&rsquo;il faudra modifier pour aller sur des fr\u00e9quences plus hautes ou plus basses&#8230;<\/p>\n\n\n<h4 class=\"wp-block-heading\">Exemple sur le Pr\u00e9sident Jackson I<\/h4>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">Le Jackson 1er du nom est donc \u00e9quip\u00e9 de la PLL MC145106 dont voici la <a href=\"http:\/\/192.168.1.23\/wordpress\/wp-content\/uploads\/2020\/04\/MC145106_datasheet.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">datasheet<\/a>.<\/p><\/p>\n\n\n<p class=\"wp-block-paragraph\"><p style=\"text-align: justify;\">pour lui ajouter les INF3, il va falloir rentrer le code binaire de la bande : 00010101 sur les additionneurs CD4008 dont voici la <a href=\"http:\/\/192.168.1.23\/wordpress\/wp-content\/uploads\/2020\/04\/CD4008_datasheet.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">datasheet<\/a>, correspondant au nombre d\u00e9cimal 22 (67 \u2013 45), ou bien encore 26.065MHz (fr\u00e9quence du canal 1 en INF2) \u2013 (45 canaux x 10kHz) = 25.615MHz (fr\u00e9quence du canal 1 en INF3)\u2026<\/p><\/p>\n\n\n<p class=\"wp-block-paragraph\">Prenons le sch\u00e9ma du c\u00f4t\u00e9 PLL et additionneurs\u2026<\/p>\n\n\n<h4 class=\"wp-block-heading\"><br \/><br \/><img decoding=\"async\" class=\"wp-image-746\" style=\"width: 1000px;\" src=\"http:\/\/192.168.1.23\/wordpress\/wp-content\/uploads\/2020\/04\/PLL_schema.png\" alt=\"\"><\/h4>\n","protected":false},"excerpt":{"rendered":"<p>Les PLL (Phased Locked Loop) ou boucle \u00e0 verrouillage de phase sont les composants cl\u00e9s de la s\u00e9lection de bande, avec quelques modifications elles permettent d\u2019obtenir plus de canaux sur les postes C.B. afin d\u2019\u00e9couter d\u2019autres bandes car rappelons qu\u2019il est interdit de moduler en dehors des 40 canaux\u2026 C\u2019est un circuit int\u00e9gr\u00e9 faisant office &hellip; <a href=\"https:\/\/ordi-tech.fr\/index.php\/les-pll-2\/\" class=\"more-link\">Continuer la lecture de <span class=\"screen-reader-text\">Les PLL<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-866","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/pages\/866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/comments?post=866"}],"version-history":[{"count":0,"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/pages\/866\/revisions"}],"wp:attachment":[{"href":"https:\/\/ordi-tech.fr\/index.php\/wp-json\/wp\/v2\/media?parent=866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}